LA-302 Road Marking Road Line Retroreflectometer

Additional information

Observation angle of the instrument

1.05 degrees

Incident angle is beta

88.76 degrees

Complementary angle

1.24 degrees

Light Source Color Temperature

2856K+50K (CIEA Light Source)

The detector

silicon diode + V (lambda) rectifier, meets the

requirements of CIE standard

spectrophotometric observer spectral optical efficiency V (lambda)

The measurement range of L retroreflective

Coefficient R'is 0-3000 MCD lx-1 m-2

Battery Continuous Working Time

72 Hours

Data Storage

10,000 Test Information

Screen

4.5 "854×480

Computer Connection

TF Storage Card

Charging

220VAC 50HZ; DC8.4V

Power supply

 lithium (6600 mah)

Protection Level

 IP54

Working  temperature

– 15 C ~ + 50 C

Operating humidit

10-90%, no condensation

Volume (length x width x height)

450mm x 132 mm x 132 mm

Net weight

5kg

Product details:

Main Functional Characteristics and Technical Parameters
1. Product Basis and Standards
The instrument is designed and developed with reference to relevant international technical documents and current national standards and norms in China. It meets the requirements of No. 72 published by the International Lighting Commission (CIE), ASTM D4061-94, DIN67520, 67521 of Germany, GB/T 26377-2010 Reverse Reflectometer of China, GB/T 16311-2009 Quality Requirements and Monitoring Methods of Road Traffic Markings, JJG 059-2004 Verification Regulations of Reverse Reflectometer.
2. Measurement principle
The geometric condition of the retroreflective marking instrument is to simulate the scene observed by the driver in the cab when the headlamp illuminates the marking made of the retroreflective material on the road at night.
The angle between the optical axis of the headlamp and the normal line of the road surface (reference axis) becomes the incident angle (beta), which is set at 88.76 degrees. The angle between the optical axis of the headlamp and the reverse light is called the observation angle (alpha), which is set at 1.05 degrees. The light source and optical system are projected to the marking line according to the incident angle beta. The size of the measured marking line is 200 X 95 mm. The reflected light from the marking line is emitted to the filter equipped with V(lambda) according to the observation angle alpha of 1.05 degree. The measured value is displayed on the measuring value display after processing, that is, the measured value of the inverse reflection coefficient R’.

 

 

  1. Main parameters
Observation angle of the instrument 1.05 degrees
Incident angle is beta 88.76 degrees
Complementary angle 1.24 degrees
Light Source Color Temperature 2856K+50K (CIEA Light Source)
The detector silicon diode + V (lambda) rectifier, meets the

requirements of CIE standard

spectrophotometric observer spectral optical efficiency V (lambda)

The measurement range of L retroreflective Coefficient R’is 0-3000 MCD lx-1 m-2
Battery Continuous Working Time  72 Hours
Data Storage 10,000 Test Information
Screen 4.5 “854×480
Computer Connection TF Storage Card
Charging 220VAC 50HZ; DC8.4V
Power supply  lithium (6600 mah)
Protection Level  IP54
Working  temperature  – 15 C ~ + 50 C
Operating humidit 10-90%, no condensation
Volume (length x width x height) 450mm x 132 mm x 132 mm
Net weight 5kg

Ask For A Quick Quote

We will contact you within 1 working day, please pay attention to the email with the suffix “@gtj-test.com”