P800 Pile Integrity Tester

Pile integrity tester is a test and analysis instrument for pile integrity testing and monitoring of the precast pile driving process. Under impact or vibration load, the pile structure integrity and vertical bearing capacity of a single pile are tested and analyzed. The purpose is to determine the bearing capacity of the pile and the integrity of the pile structure.

Additional information

System Noise Voltage

Less than 2 mV

Dynamic range

More than 138dB

Amplifier Band

10Hz~10kHz

AD Resolution

16 bit A/D

Sampling time interval

2us~32768us

Sampling Length

1024,2048,4096

Time indication error

Less than 1%

Channel Number

One

Amplification factor

1~128

Data transmission mode

USB

Trigger mode

Signal triggering

Sensor Sensitivity

100 mV/g

Sensor frequency band

1-10000Hz

Continuous working hours

More than 10 hours

Power Supply

Built-in rechargeable lithium battery (+7.4V)

Display

640*480 Capacitance Screen

Operational mode

touch

Product details:

USAGE OVERVIEW

Pile integrity tester is a test and analysis instrument for pile integrity testing and monitoring of the precast pile driving process. Under impact or vibration load, the pile structure integrity and vertical bearing capacity of a single pile are tested and analyzed. The purpose is to determine the bearing capacity of the pile and the integrity of the pile structure.

 

PRODUCT FEATURES

1.The operation of the instrument is convenient and fast. From the requirement of engineering inspection, the user can quickly master the usage method;

2.Small size, light weight, easy to carry;

3.The user operates through the touch screen, and the interface is simple;

4.Support multiple waveform processing methods to make defect positioning more accurate;

5.large-capacity data memory, support for mobile storage;

6.Built-in rechargeable lithium battery, long standby time;

7.The analysis software under the Windows platform has comprehensive functions and flexible printing settings. It can print preview and output processing results and can generate test reports.

TECHNICAL PARAMETERS

Product Model P800
System Noise Voltage Less than 2 mV
Dynamic range More than 138dB
Amplifier Band 10Hz~10kHz
AD Resolution 16 bit A/D
Sampling time interval 2us~32768us
Sampling Length 1024.2048.4096
Time indication error Less than 1%
Channel Number One
Amplification factor 1~128
Data transmission mode USB
Trigger mode Signal triggering
Sensor Sensitivity 100 mV/g
Sensor frequency band 1-10000Hz
Continuous working hours More than 10 hours
Power Supply Built-in rechargeable lithium battery (+7.4V)
Display 640*480 Capacitance Screen
Operational mode touch